Chapter #12 - Appendix - SNMP 276 000001628
MaxAttach NAS 6000 Administration Guide
Chapter #12 - Appendix - SNMP
MIB Specifications
11/07/01 -- Revision 2.0.03A
MaxAttach SNMP Traps
The MaxAttach supports all of the standard Microsoft Windows 2000 events, and a
number of these events pertinent to the functioning of the MaxAttach are sent as SNMP
traps. The following event categories are supported as SNMP traps:
n Disk Events (ATAPI, Disk, DiskPerf, Dmboot, Dmio, LDM)
n Power (UPS)
In addition, the MaxAttach also provides traps for its internal environmental monitoring
unit (EMU).
Table #1 - Environmental Monitoring Unit Traps
Trap Event ID Description
Trap Event ID Description
Power Supply Status 2110 Information
2310 Error
Present, Over temp, AC fail, DC fail
Fan Status 2120 Information
2320 Error
Fan running, Fan Stalled
Disk Drive Present Status 2130 Information
2330 Error
Present, Not Present
Temperature Status 2150 Information
2350 Error
Temperature Levels 1, 2, or 3, where 3 is hottest
Disk Backplane Voltage Status 2160 Information
2360 Error
Voltages Nominal (+/- 5%), Out of tolerance
Intrusion Status 2180 Information
2380 Error
Intrusion Detected